Calibration of AuxPwr Started at 23.1.2020 at 11:17:22 Set VOL target value to 1.0 Set VOH target value to 1.2 Starting test without load Started at 23.1.2020 at 11:17:23 Firmware version is 28 Enabling monitoring Enabling all voltages, using AuxPwr's built-in enable command *** Testing voltage VZK with target value 3.0 V and tolerance +- 0.1 V ADC-value is: 3.03 V Manually measured value for VZK: 2.996 measured value for voltage VZK is inside of the tolerance range *** Testing voltage VCC with target value 9.6 V and tolerance +- 0.05 V ADC-value is: 9.671 V Manually measured value for VCC: 9.5779 measured value for voltage VCC is inside of the tolerance range *** Testing voltage DI_VBIAS with target value 1.25 V and tolerance +- 0.025 V ADC-value is: 1.264 V Manually measured value for DI_VBIAS: 1.2509 measured value for voltage DI_VBIAS is inside of the tolerance range *** Testing voltage DI_VCC33ANA with target value 3.3 V and tolerance +- 0.1 V ADC-value is: 3.336 V Manually measured value for DI_VCC33ANA: 3.3012 measured value for voltage DI_VCC33ANA is inside of the tolerance range *** Testing voltage VDD12 with target value 10.65 V and tolerance +- 0.05 V ADC-value is: 10.934 V Manually measured value for VDD12: 10.8082 !!! info: measured value for voltage VDD12 is out of tolerance range !!! *** Testing voltage DI_VCC with target value 1.8 V and tolerance +- 0.03 V ADC-value is: 1.82 V Manually measured value for DI_VCC: 1.8007 measured value for voltage DI_VCC is inside of the tolerance range *** Testing voltage VCC33INT with target value 3.3 V and tolerance +- 0.1 V ADC-value is: 3.339 V Manually measured value for VCC33INT: 3.3031 measured value for voltage VCC33INT is inside of the tolerance range *** Testing voltage DI_VCCANA with target value 1.8 V and tolerance +- 0.03 V ADC-value is: 1.82 V Manually measured value for DI_VCCANA: 1.7999 measured value for voltage DI_VCCANA is inside of the tolerance range *** Testing voltage VDD25 with target value 2.5 V and tolerance +- 0.05 V ADC-value is: 2.533 V Manually measured value for VDD25: 2.5021 measured value for voltage VDD25 is inside of the tolerance range *** Testing voltage VOL with target value 1.0 V and tolerance +- 0.02 V ADC-value is: 1.01 V Manually measured value for VOL: 0.99928 measured value for voltage VOL is inside of the tolerance range *** Testing voltage VDDBUS with target value 1.0 V and tolerance +- 0.02 V ADC-value is: 1.013 V Manually measured value for VDDBUS: 1.00442 measured value for voltage VDDBUS is inside of the tolerance range *** Testing voltage VOH with target value 1.2 V and tolerance +- 0.02 V ADC-value is: 1.205 V Manually measured value for VOH: 1.2026 measured value for voltage VOH is inside of the tolerance range *** Testing voltage VCC33INT_D with target value 3.9 V and tolerance +- 0.15 V ADC-value is: 3.999 V Manually measured value for VCC33INT_D: 3.954 measured value for voltage VCC33INT_D is inside of the tolerance range *** Testing voltage VDD15TEMP with target value 15.0 V and tolerance +- 0.1 V ADC-value is: 15.132 V Manually measured value for VDD15TEMP: 14.934 measured value for voltage VDD15TEMP is inside of the tolerance range *** Testing voltage VDD5 with target value 5.5 V and tolerance +- 0.1 V ADC-value is: 5.567 V Manually measured value for VDD5: 5.5027 measured value for voltage VDD5 is inside of the tolerance range Disabling monitoring Disabling all voltages, using AuxPwr's built-in disable command Starting test with load Started at 23.1.2020 at 11:18:37 connect electronic load to VDD25 and preset a load of 3.0 A calibrate lower VDD25 current value with target value 3.0 A lower ADC-value for VDD25 is 2.131 measured value for lower calib point of VDD25 is 2.998 calibrate upper current VDD25 value with target value 20.0 A now set load for VDD25 to a value of 20.0 A upper ADC-value for VDD25 is 21.121 measured value for upper calib point of VDD25 is 19.996 A Turn off VDD25 connect electronic load to VDD5 and preset a load of 0.015 A calibrate lower VDD5 current value with target value 0.015 A lower ADC-value for VDD5 is 0.016 measured value for lower calib point of VDD5 is 0.01494 calibrate upper current VDD5 value with target value 0.15 A now set load for VDD5 to a value of 0.15 A upper ADC-value for VDD5 is 0.156 measured value for upper calib point of VDD5 is 0.1507 A Turn off VDD5 connect electronic load to DI_VBIAS and preset a load of 0.015 A calibrate lower DI_VBIAS current value with target value 0.015 A lower ADC-value for DI_VBIAS is 0.015 measured value for lower calib point of DI_VBIAS is 0.01482 calibrate upper current DI_VBIAS value with target value 0.15 A now set load for DI_VBIAS to a value of 0.15 A upper ADC-value for DI_VBIAS is 0.043 measured value for upper calib point of DI_VBIAS is 0.1506 A Turn off DI_VBIAS connect electronic load to DI_VCC and preset a load of 0.015 A calibrate lower DI_VCC current value with target value 0.015 A lower ADC-value for DI_VCC is 0.064 measured value for lower calib point of DI_VCC is 0.01489 calibrate upper current DI_VCC value with target value 8 A now set load for DI_VCC to a value of 8 A upper ADC-value for DI_VCC is 8.099 measured value for upper calib point of DI_VCC is 7.998 A Turn off DI_VCC connect electronic load to VOL and preset a load of 0.5 A calibrate lower VOL current value with target value 0.5 A lower ADC-value for VOL is 0.25 measured value for lower calib point of VOL is 0.498 calibrate upper current VOL value with target value 10 A now set load for VOL to a value of 10 A upper ADC-value for VOL is 9.75 measured value for upper calib point of VOL is 9.999 A Turn off VOL connect electronic load to VDDBUS and preset a load of 1 A calibrate lower VDDBUS current value with target value 1 A lower ADC-value for VDDBUS is 0.94 measured value for lower calib point of VDDBUS is 0.998 calibrate upper current VDDBUS value with target value 10 A now set load for VDDBUS to a value of 10 A upper ADC-value for VDDBUS is 9.767 measured value for upper calib point of VDDBUS is 9.997 A Turn off VDDBUS connect electronic load to DI_VCCANA and preset a load of 0.05 A calibrate lower DI_VCCANA current value with target value 0.05 A lower ADC-value for DI_VCCANA is 0.047 measured value for lower calib point of DI_VCCANA is 0.05044 calibrate upper current DI_VCCANA value with target value 0.6 A now set load for DI_VCCANA to a value of 0.6 A upper ADC-value for DI_VCCANA is 0.614 measured value for upper calib point of DI_VCCANA is 0.603 A Turn off DI_VCCANA connect electronic load to VOH and preset a load of 0.5 A calibrate lower VOH current value with target value 0.5 A lower ADC-value for VOH is 0.312 measured value for lower calib point of VOH is 0.497 calibrate upper current VOH value with target value 10 A now set load for VOH to a value of 10 A upper ADC-value for VOH is 9.687 measured value for upper calib point of VOH is 9.998 A Turn off VOH connect electronic load to VDD12 and preset a load of 0.015 A calibrate lower VDD12 current value with target value 0.015 A lower ADC-value for VDD12 is 0.023 measured value for lower calib point of VDD12 is 0.01501 calibrate upper current VDD12 value with target value 0.15 A now set load for VDD12 to a value of 0.15 A upper ADC-value for VDD12 is 0.155 measured value for upper calib point of VDD12 is 0.1508 A Turn off VDD12 connect electronic load to DI_VCC33ANA and preset a load of 0.1 A calibrate lower DI_VCC33ANA current value with target value 0.1 A lower ADC-value for DI_VCC33ANA is 0.088 measured value for lower calib point of DI_VCC33ANA is 0.098 calibrate upper current DI_VCC33ANA value with target value 8 A now set load for DI_VCC33ANA to a value of 8 A upper ADC-value for DI_VCC33ANA is 8.193 measured value for upper calib point of DI_VCC33ANA is 7.997 A Turn off DI_VCC33ANA calibration is now finished